杂散电流及氯离子腐蚀共同作用下钢纤维混凝土强度的试验

(1.厦门大学嘉庚学院土木工程系,福建 漳州 363105; 2.莆田学院土木工程学院,福建 莆田 351100)

杂散电流; 钢纤维混凝土; 腐蚀; 氯离子; 粉煤灰

Experimental Study on the Strength of Steel Fiber Reinforced Concrete Under the Combined Effect of Stray Current and Chloride Ion Corrosion
LIN Longbin1,LAI Xiuying2*,FENG Zhengwei1

(1.Department of Civil Engineering,Xiamen University Tan Kah Kee College,Zhangzhou 363105,China; 2.College of Civil Engineering,Putian University,Putian 351100,China)

stray current; steel fiber concrete; corrosion; chloride ion; fly ash

DOI: 10.6043/j.issn.0438-0479.201801006

备注

针对地铁工程在沿海城市海水影响地段的服役环境,设计了杂散电流腐蚀试验模拟装置,研究了钢纤维体积率、导电溶液、粉煤灰掺量和阻锈剂掺量对钢纤维混凝土腐蚀影响的主次关系; 研究了NaCl浓度和钢纤维体积率与钢纤维混凝土腐蚀后强度损失率Kc的关系.结果表明:在氯离子和杂散电流共同作用下,材料强度的损失显著,但是通过配合比优化设计可显著减小材料强度损失.研究成果可为钢纤维混凝土在地铁环境中的使用提供相关的试验基础.

Based on the service environment of the subway engineering structure in the coastal water affected areas of the city,a simulation device considering stray current effects was designed.The research carried out in this paper included that i)the influence on corrosion of steel fiber concrete affected by steel fiber volume fraction,conductive solution,fly ash content and rust inhibitor content is studied,and ii)the relationship between the loss rate of strength(Kc)and both of NaCl solution and steel-fiber volume fraction is studied.Results show that the strength of steel fiber concrete decreases significantly under the combination of chloride ion and stray cuttent,but that this loss can be remarkably reduced by the optimal mix design.They can provide some basis for the application of steel fiber concrete in the subway engineering.