关键词:
移动机器人定位超声测距角度偏向
Keywords:
mobile robot localization ultrasonic ranging angular misalignmenX.
分类号:
TP 274.53
文献标志码:
-
摘要:
针对移动机器人超声定位中超声收发传感器角度偏向造成的测距精度下降,本文提出了一种基于归一化波形参数特征修正的超声测距系统.传统的增益控制、可变阈值等抗起伏措施对抑制传播过程中的幅度起伏造成的测距误差效果较好,但如果传感器角度偏向使波形发生畸变,此类方法仍将造成较大误差.本文通过对传感器角度偏向造成接收信号波形畸变及测距精度下降的理论分析及实验研究,建立了超声接收信号归一化波形特征脉宽与前沿变化的关系,设计了基于单片机实现误差校正的大偏向角高精度超声波测距系统.测距实验结果表明本系统显著减小了传感器角度偏向引起的测距误差,在不同的距离上使测距精度平均提高了1.6%,同时具有成本低、使用简单、方便的特点.
Abstract:
To tackle the precision degradation caused by misalignment of transducer pairs in mobile robot localization,an adjustment strategy based on normalized waveform parameter is proposed to derive a high precision method for widefield ultrasonic ranging.Presently most investigation on high precision ultrasonic ranging focused on the amplitude fluctuation induced by random air medium.Nonetheless,previous research indicated that the impact of transducer misalignment on reception signal waveform can be modeled as a lowpass filter,which will cause waveform distortion of reception signal.Thus the performance of traditional approaches to improve the ultrasonic ranging precision such as automatic gain control (AGC) or variable threshold will be seriously affected under misalignment of transducer pairs.In this paper,with theoretical analysis and experimental research on the impacts of transducer misalignment,the relationship between the rising edge and characteristic width of normalized waveform is investigated,which is used to develop an adjustment approach and design a SCM (Single Chip Microcomputer) based high precision widefield ultrasonic ranging system.The experimental results show this system greatly improves the ranging precision under transducer misalignment,validating the effectiveness and convenience of the proposed scheme.Compared with traditional AGC type method,it improves the ranging precision by about 1.6%.

参考文献/References:


[1]贾莉娜.高精度的超声波测距系统在移动机器人导航方面的应用[J].计量与测试技术,2004(9):23-26.
[2]罗本成,原魁,楚坤水,等.一种超声测距的鲁棒自适应建模方法[J].机器人,2002,24(1):554-558.
[3]杨劲松,王敏,黄心汉.超声波可变阈值测距装置[J].电子技术应用,1998,24(7):7-9.
[4]王春麟.提高超声回波检测测距精度的方法[J].电测与仪表,1995,(2):22-24.
[5]童峰.自动导引车超声导引系统研究[D].厦门:厦门大学,2000.
[6]Figueroa J F,Doussis E.A hardwarelevel method to improve the range and accuracy of an ultrasonic ranging system[J].ACUSTICA,1993,78:226-232.
[7]John S Lamancusa,Fernando Figueroa J.Ranging errors caused by angular misalignment between ultrasonic transducer pairs[J]. J.Acoust Soc.American, 1990,87(3):1327-1335.
[8]童峰,许天增.一种移动机器人超声波导航系统[J].机器人,2002,24(1):55-61.
[9]Teruko Yata,Lindasy Kleeman,Shin′ichi Yuta.Fastbearin measurement with a single ultrasonic transducer[J].The International Journal of Robotics Research,1998,17(11):1202-1213.
[10]Lindsay kleeman,Oman Kuc.Mobile robot sonar for target localization and classification[J].The International Journal of Robotics Research,1995,14(4):295-318.

备注/Memo

备注/Memo:
收稿日期:20050922基金项目:国家自然科学基金(D060240476018),厦门大学科技创新基金(0050K70013)资助作者简介:孙牵宇(1982-),男,硕士研究生.*通讯作者:xmxu@xmu.edu.cn
更新日期/Last Update: 2006-07-20